Home > Look for a product > ASO High Clean Permanently Antistatic Bag

ASO High Clean Permanently Antistatic Bag

Semiconductor applications Pharmaceutical applications

ASO High Clean Permanently Antistatic Bag

ASO High Clean Permanently Antistatic Bag is an ultraclean antistatic bag that is suitable for use in a cleanroom.

Major featuresCleanHighly cleanStandard sizesSterilizedAntistaticUV protection

Request a quote/Contact us

Overview

ASO High Clean Permanently Antistatic Bag is an ultraclean antistatic bag that can be used in a cleanroom. Both the inner and outer surfaces of the bag are very clean, and particle counts on the inner surface are controlled on a lot-by-lot basis.

Conventional processing techniques that may cause bleed-out or shedding of an antistatic agent—for instance additives such as antistatic agents, carbon, heavy metals, light metals, and coatings—are not used. This product is mainly used in the semiconductor and electronic device applications, but is also safe for use in the pharmaceutical applications and it has been certified to comply with the "Test Methods for Plastic Containers" in the Japanese Pharmacopoeia, 15th edition. If you would like a copy of the catalog for this product, please do not hesitate to ask us. This product is also available in standard sizes for customers who want only a small quantity of bags.

Features

  1. Unique processing technique (patent pending)
  2. Surface specific resistance: 1013Ω or below
[Particles on the inner surface]
Specimen: High Clean Permanently Antistatic Bag (0.1mm x 250mm x 300mm)
Measurement of submicron particle counts Measurement of micron particle counts
Measurement of submicron particle counts Measurement of micron particle counts
[Measurement method]
(1) The bag was filled with 100 mL of dust-free water and then tied at the top.
(2) The bag was then shaken up and down and left to stand for at least 6 hours. Then 10 mL of the water was taken out of the bag and the number of particles in this sample was counted. This measurement was repeated three times and the average value was calculated.
[Measurement method]
(1) The bag was filled with 100 mL of dust-free water with a blank count close to zero and then tied at the top.
(2) The bag was then shaken up and down and left to stand for at least 10 minutes. Then 10 mL of the water was taken out of the bag and the number of particles in this sample was counted. This measurement was repeated three times and the average value was calculated.
* The tables show measured, not guaranteed, values.

Size / Specifications

This product is available in custom sizes.

Thickness: 0.06–0.1 mm, width: 150–1000 mm, length: 200–2000 mm
*Bag dimensions may fall outside the above ranges, depending on the bag size.

Unfortunately, we cannot answer any telephone inquiries.
If you have any questions, please contact us through the website and we will reply to your inquiry by e-mail.
Thank you for your understanding.

Go to the top of Look for a product